Service Program Mode Tables
D062/D063/D065/D066 4-18 SM Appendix
[0 to 200/10/1]
Reduce the interval for copies that contain a high proportion of black.
Vref Manual Setting
2220*
Adjusts the TD sensor reference voltage (Vref) manually.
[1 to 4/2.5/0.01 V]
Change this value after replacing the development unit with another one that
already contains toner. For example, when using a development unit from
another machine for test purposes, do the following:
Check the value of SP2220 in both the machine containing the test unit and
the machine that you are going to move it to.
Install the test development unit, then input the VREF for this unit into
SP2220.
After the test, put back the old development unit, and change SP2220 back
to the original value.
2223* Vt Display
Displays the current TD sensor output voltage.
[0 to 5 / 4 / 0.02 V]
2301* Transfer Current Adjustment
Adjusts the current applied to the transfer belt during copying.
Note: If this SP is too high, toner on the paper can go back to the drum.
001 Main: Image: Front
002 Main: Image: Back
D062: [10 to 200/50/1
A]
D063/D065: [10 to 200/65/1
A]
D066: [10 to 200/80/1
A]
003 By-pass Image: Front
D062/D063/D065: [10 to 200/75/1
A]
D066: [10 to 200/80/1
A]
004 Postcard (Japan Only)
[10 to 200/165/1
A]
005 Paper Interval
[10 to 200/15/1
A]