Timer Settings
This section describes the user tools in the Timer Settings menu under System Settings.
Auto Off Timer
After a specified period has passed, following job completion, the machine automatically turns off,
in order to conserve energy. This function is called "Auto Off".
The machine status after the Auto Off operation is referred to as "Off mode", or "Sleep mode".
For the Auto Off Timer, specify the time to elapse before Auto Off.
Default: [14 minute(s)]
The machine takes about 2 minutes to reach operation readiness after turning the power on or leaving
sleep mode.
The time can be set from 10 seconds and 240 minutes, using the number keys.
Auto Off Timer may not work when error messages appear.
Depending on which Embedded Software Architecture application is installed on it, the machine might
take longer than indicated to enter Sleep Mode.
Energy Saver Timer
Set the amount of time the machine waits before switching to lower-power mode after copying has
finished or the last operation is performed.
Default: [7 minute(s)]
The time can be set from 1 to 240 minutes, using the number keys.
Energy Saver Timer may not work when error messages appear.
Panel Off Timer
Set the amount of time the machine waits before switching the panel off after copying has finished or
the last operation is performed.
Enter a time interval between 10 seconds and 240 minutes, using the number keys.
The warm up time for making a copy from standby mode is 3 seconds for Panel off Level 1 and 15
seconds for Panel off Level 2.
Default: [On], [1 minute(s)]
Panel Off Timer may not work when error messages appear.
System Auto Reset Timer
The System Reset setting automatically switches the screen to that of the function set in Function Priority
when no operations are in progress, or when an interrupted job is cleared. This setting determines the
system reset interval.
The time can be set from 10 to 999 seconds, using the number keys.
Default: [On], [60 second(s)]