One of the following problems occurred:
The machine failed to detect a LOCK signal within two sec. after the
main motor was turned on.
The machine failed to detect a LOCK release signal with 2 sec. after
the main motor was turned off.
Cycle the machine off/on
Check the areas around motor and main drive train for a physical
obstruction (paper scraps, etc.)
Clean the main motor drive train
AIO defective
Main motor defective
SC541 C7 A Fusing Unit Thermistor Error (Fatal Error)
No temperature was detected within 5 sec. after the machine was turned
on (temperature was less than 0°C).
Fusing unit thermistor disconnected, broken or not set correctly
Fusing lamp disconnected, broken or not set correctly.
Fusing unit defective
After servicing the machine to solve the problem, the service
technician must execute a "Fuser SC Reset". Otherwise, the machine
will continue to issue this SC code and cannot be operated. (
p.202 "Executing Fuser SC Reset")
SC542 C8 A Fusing Reload Temperature Error (Fatal Error)
After starting up or during operation he machine detected after 5 readings
at 1.5 sec. intervals that the hot roller was 5°C below the reload
(operating) temperature.
Fusing thermistor deformed or out of position
Fusing lamp harness loose, broken, defective
Fusing unit defective
After servicing the machine to solve the problem, the service
technician must execute a "Fuser SC Reset". Otherwise, the machine
will continue to issue this SC code and cannot be operated. (
p.202 "Executing Fuser SC Reset")