EasyManua.ls Logo

Ricoh Aficio SP 100SF - Page 210

Ricoh Aficio SP 100SF
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC543 C9 A High Temperature Error - Software (Fatal Error)
The temperature inside the fusing unit exceeded 225°C (437°F) for more
than 1 sec.
After this error has occurred three times, the machine will shut down
and must be released with the Smart Organizing Monitor and
serviced by a service technician.
Main board defective
PSU defective (TRIAC short)
After servicing the machine to solve the problem, the service
technician must execute a "Fuser SC Reset". Otherwise, the machine
will continue to issue this SC code and cannot be operated. (
p.202 "Executing Fuser SC Reset")
SC544 c1 A High Temperature Error- Hardware (Fatal Error)
The machine detected the CPU port LOW twice at 100 ms intervals and
issued this SC. This check is always done to check for overheating, even if
SC543 does not detect the problem.
Fusing unit defective
Main board defective
PSU defective (TRIAC short)
After servicing the machine to solve the problem, the service
technician must execute a "Fuser SC Reset". Otherwise, the machine
will continue to issue this SC code and cannot be operated. (
p.202 "Executing Fuser SC Reset")
SC545 c2 A Fusing Lamp Remains ON Error (Fatal Error)
The heating element of the fusing lamp remained at full power longer than
9 sec. after the reload temperature was detected.
Fusing thermistor harness connector loose, broken, defective
Fusing thermistor warped or positioned incorrectly
Fusing lamp harness connector loose, broken, defective
After servicing the machine to solve the problem, the service
technician must execute a "Fuser SC Reset". Otherwise, the machine
will continue to issue this SC code and cannot be operated. (
p.202 "Executing Fuser SC Reset")
6. Troubleshooting