Main SP Tables-3
System Maintenance Section 2-365 D146/D147/D148/D149/D150
003 Speed Adjustment:M [-58 to 50 / 40 / 1%/step]
004 Speed Adjustment:Y [-58 to 50 / 18 / 1%/step]
3200
[TnrDensity]
Displays toner density (wt%).
001 K *ENG
[0 to 25.5 / 0 / 0.1 wt%/step]
002 C *ENG
003 M *ENG
004 Y *ENG
3201
[TnrDensity]
Sets min./max. density (wt%) for toner density controlling range.
001 Upper TC *ENG [1.0 to 15.0 / 9.0 / 0.1wt%/step]
002 Lower TC *ENG [1.0 to 15.0 / 2.0 / 0.1wt%/step]
3205
[TD.Sens Sensitivity]
Displays TD sensor sensitivity HL calculated from test value of HST density
control (SP3-711 to 714-***)
001 HL:K *ENG
[0.200 to 1.000 / 0.350 /
0.001-V/wt%/step]
002 HL:C *ENG
003 HL:M *ENG
004 HL:Y *ENG
3205
[TD.Sens Sensitivity]
Displays TD sensor sensitivity HM calculated from test value of HST density
control (SP3-711 to 714-***)
011 HM:K *ENG
[0.200 to 1.000 / 0.350 /
0.001-V/wt%/step]
012 HM:C *ENG