Main SP Tables-3
D146/D147/D148/D149/D150 2-366 System Maintenance Section
013 HM:M *ENG
014 HM:Y *ENG
3205
[TD.Sens Sensitivity]
Displays TD sensor sensitivity ML calculated from test value of HST density
control (SP3-711 to 714-***)
021 ML:K *ENG
[0.200 to 1.000 / 0.350 /
0.001-V/wt%/step]
022 ML:C *ENG
023 ML:M *ENG
024 ML:Y *ENG
3205 [TD.Sens Sensitivity]
031
Upper Limit *ENG
[0.200 to 0.500 / 0.440 /
0.001-V/wt%/step]
Sets max. sensitivity for to calculate TD sensor sensitivity.
032
Lower Limit *ENG
[0.150 to 0.500 / 0.180 /
0.001-V/wt%/step]
Sets min. sensitivity for to calculate TD sensor sensitivity.
033
TC Between H-M:K *ENG [1.00 to 10.00 / 4.50 / 0.01wt%
Sets HM interval as TC of K for to calculate TD sensor sensitivity.
034
TC Between M-L:K *ENG [1.00 to 10.00 / 4.40 / 0.01wt%
Sets ML interval as TC of K for to calculate TD sensor sensitivity.
043
TC Between H-M:Col *ENG [1.00 to 10.00 / 4.20 / 0.01wt%
Sets HM interval as TC of CMY for to calculate TD sensor sensitivity.
044
TC Between H-M:Col *ENG [1.00 to 10.00 / 4.40 / 0.01wt%
Sets ML interval as TC of CMY for to calculate TD sensor sensitivity.
3210
[TD.Sens:Vt :Disp]
Displays latest T sensor output.