Main SP Tables-3
System Maintenance Section 2-367 D146/D147/D148/D149/D150
SP Mode Tables
001 Current: K *ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
002 Current: C *ENG
003 Current: M *ENG
004 Current: Y *ENG
3211 [Vt Limits Err :Disp]
002
Upper Threshold *ENG [0.00 to 5.00 / 4.70 / 0.01V/step]
Sets Vt upper limit threshold to decide as Vt upper limit error.
003
Thresh Num of UpperCounter *ENG [0 to 255 / 20 / 1times/step]
Sets the number of times excessing Vt upper limit to set off SC360 to 363 (Vt
upper limit error).
004
Lower Threshold *ENG [0.00 to 5.00 / 0.50 / 0.01V/step]
Sets Vt upper limit threshold to decide as Vt lower limit error.
005
Threshold Num of
LowerCounter
*ENG [0 to 255 / 10 / 1times/step]
Sets the number of times excessing Vt lower limit to set off SC365 to 363 (Vt
upper limit error).
3211
[Vt Limits Err :Disp]
Counts times of Vt(K/C/M/Y) excessing Vt upper limit threshol
011 Upper Counter: Bk *ENG
[0 to 255 / 0 / 1times/step]
012 Upper Counter: C *ENG
013 Upper Counter: M *ENG
014 Upper Counter: Y *ENG
3211
[Vt Limits Err :Disp]
Counts times of Vt(K/C/M/Y) excessing Vt lower limit threshold.
021 Lower Counter: Bk *ENG
[0 to 255 / 0 / 1times/step]
022 Lower Counter: C *ENG