Main SP Tables-3
D146/D147/D148/D149/D150 2-368 System Maintenance Section
023 Lower Counter: M *ENG
024 Lower Counter: Y *ENG
3212
[Vt Shift :Set]
Sets middle speed correction amount for correcting Vt shift caused by line
speed.
001
Mid Spd:K
*ENG
[0.00 to 2.55 / D146, D147: 8 D148:
0 D149, D150: 3 / 0.01V/step]
002 Mid Spd:C *ENG
[0.00 to 2.55 / 0.07 / 0.01V/step]
003 Mid Spd:M *ENG
004 Mid Spd:Y *ENG
3212
[Vt Shift :Set]
Sets low speed correction amount for correcting Vt shift caused by line speed.
011 Low Spd:K *ENG
[0.00 to 2.55 / 0.14 / 0.01V/step]
012 Low Spd:C *ENG
013 Low Spd:M *ENG
014 Low Spd:Y *ENG
3212
[Vt Shift :Set]
Sets ON/OFF TC correction amount of Vt shift.
101
ON/OFF
*ENG
[0 or 1 / 1 / 1/step]
0: OFF
1:ON
3212
[Vt Shift :Set]
Displays TC correction amount of Vt shift.
111 TC Mid Spd:K *ENG
[-0.50 to 0.50 / 0.00 / 0.01V/step]
112 TC Mid Spd:C *ENG
113 TC Mid Spd:M *ENG