Main SP Tables-3
System Maintenance Section 2-373 D146/D147/D148/D149/D150
SP Mode Tables
011
Lower:K *ENG [0.00 to 5.00 / 2.00 / 0.01V/step]
Sets lower limit for target value of TD sensor's output voltage: Vtref (K).
012
Lower:C *ENG [0.00 to 5.00 / 2.00 / 0.01V/step]
Sets lower limit for target value of TD sensor's output voltage: Vtref (C).
013
Lower:M *ENG [0.00 to 5.00 / 2.00 / 0.01V/step]
Sets lower limit for target value of TD sensor's output voltage: Vtref (M).
014
Lower:Y *ENG [0.00 to 5.00 / 2.00 / 0.01V/step]
Sets lower limit for target value of TD sensor's output voltage: Vtref (Y).
3232 [Vtref Correct:Pixel]
001
ON/OFF *ENG
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
Switches ON/OFF pixel Vtref correction.
3232
[Vtref Correct:Pixel]
Sets coefficient to decide Vtref correction value of Vtref correction by image
area.
Vtref correction value: SP3-222-009 to 012 = calculated Vtref correction value
small area coefficient (This SP)
How to use this SP: Vtref correction by image area.
011 Low Coverage Coef:K *ENG
[0.0 to 5.0 / 1.0 / 0.1/step]
012 Low Coverage Coef:C *ENG
013 Low Coverage Coef:M *ENG
014 Low Coverage Coef:Y *ENG
3232 [Vtref Correct:Pixel]