Main SP Tables-3
D146/D147/D148/D149/D150 2-386 System Maintenance Section
3320 [Vsg Adj: Execute]
001
P Sensor ENG
[0 or 1 / 0 / 1/step]
[Execute]
Adjusts Vsg.
012
Voffset Threshold *ENG [0.00 to 5.00 / 1.00 / 0.01V/step]
Sets upper limit threshold of Voffset error.
013
Vsg Upper Threshold *ENG [0.00 to 5.00 / 4.50 / 0.01V/step]
Sets upper limit threshold of Vsg adjust error.
014
Vsg Lower Threshold *ENG [0.00 to 5.00 / 3.50 / 0.01V/step]
Sets lower limit threshold of Vsg adjust error.
015
Ifsg UpperLimit *ENG [0.0 to 50.0 / 30.0 / 0.1mA/step]
Sets error decision threshold of SC382 (If upper limit error).
020
Interval :Set *ENG [0 to 2000 / 0 / 1page/step]
Sets Vsg adjusting execute page interval to be decided after or during printing.
§ Will be executed when Pro-Con or MUSIC decides necessity. (Won't
work alone)
021
Page Cnt *ENG [0 to 2000 / 0 / 1page/step]
Displays Page counter for Vsg execute decision.
031
Vsg Error Counter (Front) *ENG [0 to 99 / 0 / 1times/step]
Counts Vsg error.
032
Vsg Error Counter (Center) *ENG [0 to 99 / 0 / 1times/step]
Counts Vsg error.
033
Vsg Error Counter (Rear) *ENG [0 to 99 / 0 / 1times/step]
Counts Vsg error.
3321 [Adjusted Vsg]