D163 106 SM
* This setting can be used for the remote machine.
System Switch 1A (SP No. 1-101-027)
No Function Comments
0
to
7
LS RX memory capacity
threshold setting
00-FF (0-1020 Kbyte: Hex)
Sets the value to x4KB. When the amount of
available memory drops below this setting, RX
documents are printed to conserve memory.
Initial setting 0x80 (512 KB)
NOTE: If a customer wants available memory
size to be larger, decrease this threshold
System Switch 1B - Not used (do not change these settings)
System Switch 1C - Not used (do not change these settings)
System Switch 1D (SP No. 1-101-030)
No Function Comments
0
RTI/CSI/CPS code display
0: Enable
1: Disable
0: RTI, CSI, CPS codes are displayed on the
top line of the LCD panel during
communication.
1: Codes are switched off (no display)
1-7 Not used Do not change these settings.