Service Call 620-689
D146/D147/D148/D149/D150 5-92 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC635-00 B
Counter device error 4
A backup battery error was returned by the counter device.
Counter device control board or the backup battery of counter
device defective
§ Replace the counter device control board.
§ Replace the backup battery.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC636-01 D
IC Card Error (Expanded authentication module error)
Issued when expanded authentication management is set to
"ON" but either of the following occur.
§ There is no expanded authentication module in the
machine.
§ The SD card or the file of the expanded authentication
module is broken.
§ There is no DESS module in the machine.
§ There is no DESS module in the machine (models on which
the function is optional).
§ There is no expanded authentication module in the
machine.
§ The SD card or the file of the expanded authentication
module is broken.
§ Set a working SD card/expanded authentication module file.
§ Install the DESS module.
§ In the SSP mode set SP5-401-160 to 0.
§ In the SSP mode, set SP5-401-161 to 0.
§ Replace the NVRAM.