Service Call 620-689
SM 5-95 D146/D147/D148/D149/D150
Troubleshooting
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC650-04 B
Remote Service Modem Communication Error (dialup failing
because of incorrect modem configuration)
§ An error related to communication (dialup connection,
modem board etc.) using the RC Gate Type M was detected
or an error that prevents RC Gate operation was detected at
power on.
§ Displayed only when an error is detected while RC Gate is
operating.
§ SC is not issued if an error occurs during RC Gate
installation (because it can be referenced using SP).
Dialup failing because of incorrect modem configuration
Check if the setting of SP5-816-160 is correct.
If it is correct, then there is a software bug.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC650-05 B
Remote Service Modem Communication Error (insufficient
current or connection fault)
§ An error related to communication (dialup connection,
modem board etc.) using the RC Gate Type M was detected
or an error that prevents RC Gate operation was detected at
power on.
§ Displayed only when an error is detected while RC Gate is
operating.
§ SC is not issued if an error occurs during RC Gate
installation (because it can be referenced using SP).
Insufficient current or connection fault
The line is not supported and nothing can be done.