Service Call 816-899
D146/D147/D148/D149/D150 5-166 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-20 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "s".)
§ Format the HDD.
§ Replace the HDD.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-21 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "t".)
§ Format the HDD.
§ Replace the HDD.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC864-22 D
HDD data CRC error
During HDD operation, the HDD returned a CRC error.
Bad sectors were generated during operation.
(An error occurred in partition "u".)
§ Format the HDD.
§ Replace the HDD.