Main SP Tables-2-2
D146/D147/D148/D149/D150 2-280 System Maintenance Section
2554
[OHP:Size-Env.Correct:FC]
Sets paper transfer ampere paper size environment correction per mode
(FC/BW) of OHP. (When using optional wide unit.)
023 Wide Roller:PaperTransfer:S1 *ENG [1 to 100 / 77 / 1/step]
027 Wide Roller:PaperTransfer:S2 *ENG [1 to 100 / 78 / 1/step]
031 Wide Roller:PaperTransfer:S3 *ENG [1 to 100 / 79 / 1/step]
035 Wide Roller:PaperTransfer:S4 *ENG [1 to 100 / 79 / 1/step]
039 Wide Roller:PaperTransfer:S5 *ENG [1 to 100 / 79 / 1/step]
2555
[OHP:LeadingEdgeCorrection]
Sets output value [%] for paper transfer ampere leading edge correction of
OHP.
003 Paper Transfer *ENG [0 to 995 / 100 / 5%/step]
2556
[OHP:SwitchTimingLeadEdge]
Sets switch timing for paper transfer ampere leading edge correction of OHP.
003 Paper Transfer *ENG [0 to 50 / 0 / 2mm/step]
2557
[OHP:TrailEdgeCorrection]
Sets output value [%] for paper transfer ampere trailing edge correction of OHP.
003 Paper Transfer *ENG [0 to 995 / 100 / 5%/step]
2558
[OHP:SwitchTimingTrailEdge]
Sets switch timing for paper transfer ampere trailing edge correction of OHP.
003 Paper Transfer *ENG [0 to 50 / 0 / 2mm/step]
2563 [Special1:Bias:BW]