Mode No. Function Settings
49
Fusing
Temperature
Adjustment
Adjusts the control temperature of the hot roller
during copying in 1
°
C steps.
120 V Machines
180
°
C ~ 195
°
C
Default = 190
°
C
230 V Machines
180
°
C ~ 200
°
C
Default = 190
°
C
50
Fusing Ready
Temperature
Adjustment
Adjusts the ready temperature of the hot roller
during the warm-up period in 1
°
C steps.
120 V Machines
160
°
C ~ 170
°
C
Default = 165
°
C
230 V Machines
165
°
C ~ 175
°
C
Default = 172
°
C
Normally, this value should not be changed.
51
Exposure
Lamp Voltage
Display
Displays the current exposure lamp voltage.
For 120 V machines, the actual applied
voltage = displayed value/2
0 ~ 247
The exposure lamp turns on for 10 seconds when
this mode is selected. Do not repeat more than 5
times, to avoid overheating the optics cavity.
52
Fusing
Temperature
Display
✝
Displays the fusing temperature detected by the
fusing thermistor.
Press the
key to monitor the temperature
during the normal copy cycle.
53
TD Sensor
Target Control
Voltage
Adjustment
If the setting of SP30 (Toner Supply Mode
Selection) is 1 or 3, this value is used for the TD
sensor target voltage.
1 ~ 200
Default = 97
(0.02 V per
step)
Normally, this value should not be changed.
54
TD Sensor
Gain
Adjustment
When the TD Sensor initial setting is performed, this
mode is adjusted automatically.
0 ~ 255
Default = 149
(0.04 V per
step)
Normally, this value should not be changed.
55
TD Sensor
Output Display
Data
✝
Displays the TD sensor output voltage.
Press the
key to monitor the output voltage
during the normal copy cycle.
The output voltage will display "0" when this mode is
accessed after turning on the main switch without
making any copies.
(0.02 V per
step) x Data
56
ADS
Reference
Voltage
Adjustment
Adjusts the ADS reference voltage.
After adjusting the light intensity (SP48), place 5
sheets of A4(LT) white paper on the exposure glass
and select this mode. Adjust the ADS voltage to 2.5
V
±
0.1 V using VR101 on the main control board.
57
ADS Output
Voltage
Display
✝
Displays the ADS output voltage.
Press the
key to monitor the output voltage
during the normal copy cycle.
For only this SP mode, the copies are made with the
ADS mode (other SP modes use manual ID level 4).
PROGRAM MODES 20 December 1996
4-18