3.2 INSTALLATION PROCEDURE
CAUTION
When installing the DF, make sure the copier is unplugged.
1. Remove the platen cover [A] from the copier.
2. Replace the 2 screws with the 2 stud screws [B].
Use the M3 stud screws for A219.
Use the M4 stud screws for A203.
3. Remove the strips of tape from the DF.
CAUTION
The next step (step 4) must be done only in 240 volt areas.
4. Perform the conversion from 220
230 V to 240 V as follows:
1) Remove the main board cover [C] (2 screws).
2) Disconnect the connector for 220
230 V [D] (Black Wire) from the ac
harness connector [E] and connect the connector for 240 V [F] (White
Wire) to the ac harness connector.
3) Reinstall the cover.
[A]
[B]
A662I500.wmf
[F] 230 ~ 240 V
[D] 220 ~ 230 V
[C]
[E]
A662I501.img
Installation
20 December 1996 DOCUMENT FEEDER (A662)
3-9