SC Table
G133 4-72 SM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
HDD mail transfer error
An error is detected in the HDD at machine initialization.
Defective HDD
Power failure during an access to the HDD
873
CTL
B
1. Initialize the HDD partition (SP5-832-008).
2. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Delete All error 1: HDD
An error is detected while all of the HDD or NVRAM are formatted
physically by the Data Overwrite Security Unit (G874).
Data Overwrite Security Unit (SD card) not installed
Defective HDD
874
CTL
D
1. Install the Data Overwrite Security Unit (G874).
2. Replace the HDD.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Delete All error 2: Data area
An error is detected while all of the HDD or NVRAM are formatted
logically by the Data Overwrite Security Unit (G874).
The logical format for the HDD fails.
875
CTL
D
Turn the main switch off/on and try the operation again
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
876
CTL
D
Log Data Error
An error was detected in the handling of the log data at power on or