Service Mode Table
SM 5-27 G133
Service
Tables
1901 [Recovery Temp. Ope. Time]
004 - *ENG
[0 to 60 / 10 / 1 sec/step] Not used
1902 [Drum Phase Adj.]
001 Execute - Execute drum phase adjustment.
002 Result *ENG
Displays the result of drum phase
adjustment.
0: Successfully done
2: Sampling failure
3: Insufficient detection number
003 Auto Execution *ENG
Turns the automatic drum phase
adjustment on or off.
0: Off, 1: On
1907 [Paper Feed Timing Adj.] DFU
001 Pre-Feed *ENG
[0 or 1 / 0 / - ]
002 Feed Solenoid ON: Plain *ENG
[–10 to 40 / 0 / 2.5 mm/step]
003 Feed Clutch OFF: Plain *ENG
[–10 to 10 / 0 / 1 mm/step]
004 Feed Clutch ON: Plain *ENG
[–10 to 10 / 0 / 1 mm/step]
005 Inverter Stop Position *ENG
[–10 to 10 / 0 / 1 mm/step]
006 Re-Feed Stop Position *ENG
[–10 to 10 / 0 / 1 mm/step]
007 By-pass Solenoid OFF *ENG
[0 to 40 / 0 / 1 mm/step]
008 By-pass Solenoid Re-ON *ENG
[0 or 1 / 1 / - ]
010 By-pass Feed Clutch ON *ENG
[–10 to 10 / 0 / 1 mm/step]
012 Feed Solenoid ON: Thick *ENG
[–10 to 40 / 0 / 2.5 mm/step]
013 Feed Clutch OFF: Thick *ENG
[–10 to 10 / 0 / 1 mm/step]