Service Mode Table
G133 5-58 SM
001 M Magnification *ENG
002 C Magnification *ENG
003 Y Magnification *ENG
Adjusts the line position manually.
[-1 to 1 / 0 / 0.001%/step]
When line shifts are not corrected by the
automatic line position adjustment, do this
SP.
Increasing a value reduces the image in the
main scan direction.
Decreasing a value enlarges the image in
the main scan direction.
004-021
Adjusts the main scan registration for each color and speed.
Decreasing a value makes the image shift to the left side on the print.
Increasing a value makes the image shift to the right side on the print.
1 dot = 21μm, 1 pulse = 1.3μm
Dot: Rough adjustment, Subdot: Fine adjustment. Adjust ‘dot’ first, then adjust
‘subdot’.
004 M. Scan: High: Dot: M *ENG
[-512 to 512 / 0 / 1 dot/step]
005 M. Scan: High: Subdot: M *ENG
[-15 to 15 / 0 / 1 pulse/step]
006 M. Scan: Medium: Dot: M *ENG
[-512 to 512 / 0 / 1 dot/step]
007
M. Scan: Medium: Subdot:
M
*ENG
[-15 to 15 / 0 / 1 pulse/step]
008 M. Scan: Low: Dot: M *ENG
[-512 to 512 / 0 / 1 dot/step]
009 M. Scan: Low: Subdot: M *ENG
[-15 to 15 / 0 / 1 pulse/step]
010 M. Scan: High: Dot: C *ENG
[-512 to 512 / 0 / 1 dot/step]
011 M. Scan: High: Subdot: C *ENG
[-15 to 15 / 0 / 1 pulse/step]
012 M. Scan: Medium: Dot: C *ENG
[-512 to 512 / 0 / 1 dot/step]
013
M. Scan: Medium: Subdot:
C
*ENG
[-15 to 15 / 0 / 1 pulse/step]
014 M. Scan: Low: Dot: C *ENG
[-512 to 512 / 0 / 1 dot/step]
015 M. Scan: Low: Subdot: C *ENG
[-15 to 15 / 0 / 1 pulse/step]