Time *ENG
[1 to 1440 / 300 / 1 minute/step]
009
Adjust the time threshold for the line position adjustment (Mode b: adjustment
once). The timing for line position adjustment depends on the combinations of
several conditions. For details, see ‘p.6-3 "Automatic Line Position
Adjustment"’ in the "Detailed Section Descriptions" section.
Magnification *ENG
[0 to 10 / 1 / 0.1%/step]
010
Adjusts the magnification threshold for line position adjustment. If the length of
the main scan is changed by this amount since the previous MUSIC, then
MSUIC is done again.
Temp . 2 * E NG
[0 to 100 / 10 / 1°C/step]
011
Adjust the temperature change threshold for the line position adjustment
(Mode a: adjustment twice). The timing for line position adjustment depends on
the combinations of several conditions. For details, see ‘p.6-3 "Automatic Line
Position Adjustment"’ in the "Detailed Section Descriptions" section.
Time 2 *ENG
[1 to 9999 / 600 / 1 minute/step]
012
Adjust the time threshold for the line position adjustment (Mode a: adjustment
twice). The timing for line position adjustment depends on the combinations of
several conditions. For details, see ‘p.6-3 "Automatic Line Position
Adjustment"’ in the "Detailed Section Descriptions" section.
2194 [MUSIC Execution Result] Line Position Adjustment: Execution Result
001 Year *ENG
[0 to 99 / 0 / 1 year/step]
002 Month *ENG
[1 to 12 / 1 / 1 month/step]
003 Day *ENG
[1 to 31 / 1 / 1 day/step]
004 Hour *ENG
[0 to 23 / 0 / 1 hour/step]
005 Minute *ENG
[0 to 59 / 0 / 1 minute/step]
006 Temperature *ENG
[0 to 100 / 0 / 1 page/step]