Service Mode Table
G133 5-184 SM
002 Potential Control: FC *ENG
003 Power ON: BW *ENG
004 Power ON: FC *ENG
005 MUSIC: BW *ENG
006 MUSIC: FC *ENG
007 Vsg Adj. *ENG
008 Charge AC Control *ENG
[Execution Interval: Setting]
3511
Adjusts the threshold for each adjustment mode.
001 Job End: Potential Control: BW *ENG
[0 to 2000 / 250 / 1 page/step]
002 Job End: Potential Control: FC *ENG
[0 to 2000 / 100 / 1 page/step]
003 Interrupt: Potential Control: BW *ENG
[0 to 2000 / 500 / 1 page/step]
004 Interrupt: Potential Control: FC *ENG
[0 to 2000 / 200 / 1 page/step]
005
Power ON: Potential Control:
BW
*ENG
[0 to 2000 / 200 / 1 page/step]
006
Power ON: Potential Control:
FC
*ENG
[0 to 2000 / 100 / 1 page/step]
007 Vsg Adj. Counter *ENG
[0 to 2000 / 500 / 1 page/step]
008 Charge AC Control Counter *ENG
[0 to 2000 / 500 / 1 page/step]
019 Environmental Correction *ENG
[0 or 1 / 1 / 1 /step]
0: Not Correct (OFF), 1: Correct
(ON)
020 Gamma Correction *ENG
[0 or 1 / 1 / 1 /step]
0: Not Correct (OFF), 1: Correct
(ON)