Service Mode Table
G133 5-198 SM
replaced before the machine detects
used toner near full when this setting is
set to "0", the machine cannot detect
toner collection bottle near full. In that
case, set SP3-902-017 to "1".
[Toner Collection Bottle Full Detection]
3900
Turns toner collection bottle full detection on or off.
001 ON/OFF Setting *ENG
[0 or 1 / 1 / - ]
0: OFF, 1: ON
[New PCU Detection]
3901
Turns new PCU detection on or off.
001 ON/OFF Setting *ENG
[0 or 1 / 1 / - ]
0: OFF, 1: ON
[Manual New Unit Set]
3902
Turns the new unit detection flag for each PM unit on or off.
The use of these counters is explained in the PM section and in the relevant
parts of section 3 (Replacement and Adjustment).
009 PCU: Bk *ENG
010 PCU: Y *ENG
011 PCU: M *ENG
012 PCU: C *ENG
[0 or 1 / 0 / - ]
0: OFF, 1: ON
013 Image Transfer Unit *ENG
014 Fusing Unit *ENG
017 Toner Collection Bottle *ENG
[0 or 1 / 0 / - ]
0: OFF, 1: ON
Do not use 3902-013 if you only change
the cleaning unit.