Service Mode Table
G133 5-204 SM
The timer is advanced by 1 hour at am 0:00 on the 5th Sunday in March
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
End - -
004
Specifies the end setting for the summer time mode.
There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12]
3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday]
5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
[Access Control]
5401
When installing the SDK application, SAS (VAS) adjusts the following
settings. DFU
200 SDK1 Unique ID *CTL
This ID is overwritten by SAS (VAS) when
you install or uninstall the SDK application.
201
SDK1 Certification
Method
*CTL
[0 to 255 / 0 / 1 /step]
210 SDK2 Unique ID *CTL -
211
SDK2 Certification
Method
*CTL
[0 to 255 / 0 / 1 /step]
220 SDK3 Unique ID *CTL -
221
SDK3 Certification
Method
*CTL
[0 to 255 / 0 / 1 /step]
5404 [User Code Counter Clear]