Service Mode Table
SM 5-205 G133
Service
Tables
001 UCodeCtrClr Clears all counters for users.
5501 [PM Alarm]
*CTL -
001 PM Alarm Level
[0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when Value (1 to 9999)
x 1000 PM counter
5504 [Jam Alarm]
*CTL -
001
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[0 to 3 / 3 / 1 /step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
[Error Alarm]
5505
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when an SC is not detected during a set
number of printed sheets (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
001 - *CTL
[0 to 255 / 40 / 100 pages /step]
5507 [Supply Alarm]
*CTL -
001 Paper Supply Alarm
0: Off, 1: On
002 Staple Supply Alarm
0: Off, 1: On
003 Toner Supply Alarm
0: Off, 1: On