Parameter Description Range Default
1 Key 1 = Zero key
2 = Tare key
3 = Gross/net key
4 = Function 1 key
5 = Function 2 key
6 = Function 3 key
-
2 Duration of key press 0 = Short press
1 = Long press
0 (short press)
Example
Command Answer Description
S01; Select unit 1
FPL?; "0476003F088100000000000000000000"CRLF Get current display buffer
FPL1; 0 CRLF Simulate short press of the zero key
FPL2,0; 0 CRLF Simulate short press of the tare key
FPL3,1; 0 CRLF Simulate long press of the gross/net key (enter
setup)
21.3.22 IAD: Scale Build
Set the scale build parameters including max1,e1,max2,e2,decimal point etc.
General
No. of parameters 7
Save changes With TDD1
Increment Trade Counter Yes
Parameter Details
Parameter Description Range Default
1 Range 1 .. 2 1
2 Maximum Load
(max1 or max2)
100 .. 999999 Range 1: 3000
Range 2: 6000
3 Number of right side digits
(decimal point position)
0 .. 5 0
4 Resolution (e1 or e2) 1 = 1
2 = 2
3 = 5
4 = 10
5 = 20
6 = 50
7 = 100
Range 1: 1
Range 2: 2
5 x10 mode 0 = Off
1 = On
0
6 Additive Tare 0 .. full scale 0
7 Sense line check 0 = Off
1 = On
1
Note
The full scale weight of the instrument is set to nominal load 1 for single range
installations, and nominal load 2 for dual-range and dual-interval installations. In
single range installations nominal load 2 is not used.
Example
135 C500-600-2.0.3