Error Code Error Description
0500
H
Write Error
0501
H
Permission error You do not have permission to write to this register.
0502
H
Unknown type error Internal error: Register type is not known to RinCmd.
0503
H
No type data error Internal error: Unable to write to the registers data structure.
0504
H
Command error The CMD is not valid for this register type.
0505
H
Parse error Unable to parse the data for the command type. If this is a decimal
write, ensure all characters numbers. If this is a hexadecimal write,
ensure all characters are hex (0-9, A-F). If this is a string register,
the characters are outside the range of the
0506
H
Range low error The value that is attempting to be written is below the minimum
for the register.
0507
H
Range high error The value that is attempting to be written is above the maximum
for the register.
0508
H
Length low error The string that is attempting to be written to the register is below
the minimum length.
0509
H
Length low error The string that is attempting to be written to the register is above
the maximum length.
050A
H
Null register error The register cannot be found.
050B
H
Buffer size error Internal error: The entire string is not able to be written to the
buffer.
050C
H
Snprintf error A function within the library has failed to run correctly.
050D
H
Snprintf error A function within the library has failed to run correctly.
050E
H
Type length error A number above the maximum for the register cannot be written
(e.g. UINT8 register cannot store a number greater than 255.)
0600
H
Exec Error
0601
H
Permission error You do not have permission to execute this register.
0602
H
Unknown type error Internal error: Register type is not known to RinCmd.
0603
H
No type data error Internal error: Unable to execute using the registers data structure.
0604
H
Command error The CMD is not valid for this register type.
0605
H
Null register error The register cannot be found.
0606
H
Writeback error The register execute function returned an improper value.
0700
H
Not Implemented Error A non-implemented CMD was given.
18.3 rinCMD Examples
Read Gross Weight
COMMAND A:
20110026:;
COMMAND A:
Read Gross Weight (Register 0026
H
):
ADDR = 20
H
: Reply required from any instrument
CMD = 11
H
: Read Final
REG = 0026
H
: Gross Weight
RESPONSE A:
81110026:00000064;
RESPONSE A:
Response is from instrument #1 which currently has a Gross weight
of 64
H
(100) kg.
75 C500-600-2.0.3

Table of Contents

Other manuals for Rinstrum C530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum C530 and is the answer not in the manual?

Rinstrum C530 Specifications

General IconGeneral
BrandRinstrum
ModelC530
CategoryTouch Panel
LanguageEnglish

Related product manuals