Command Answer Description
S01; Select unit 1
PST?1; " Weight "CRLF Query line 1 data
PST?2; " Ticket "CRLF Query line 2 data
PST1,"Joe Bloggs Pty Ltd"; 0 CRLF Change line 1
PST2,"ph 3312 1234"; 0 CRLF Change line 2
TDD1; 0 CRLF Save setting
21.3.43 QAF: Maintenance Date
General
No. of parameters 4
Save changes With TDD1
Increment Trade Counter No
Parameter Details
Parameter Description Range Default
1 Enable 0 = Off
1 = On
0
2 Day 1 .. 31 1
3 Month 1 .. 12 1
4 Year 0 .. 99 or 1998 .. 2097 2010
Note
When reading QAF?;, the year is always returned as short year (0 .. 99). When
writing the year using QAF, either short year (0 .. 99) or long year (1998 .. 2097)
formats can be used.
Example
Command Answer Description
S01; Select unit 1
QAF?; 0,15,6,00 CRLF QA function off, date currently set to 15/6/2000
QAF1,29,11,2016; 0 CRLF Turn QA function on and set date to 29/11/16
QAF1,29,11,16; 0 CRLF Turn QA function on and set date to 29/11/16
TDD1; 0 CRLF Save setting
21.3.44 RBT: Remote Keys
Setup the functions of each of the 8 remote inputs or artificially force the execution of the function. This may
be used to implement the extended features without external keys and no need of the option cards.
General
No. of parameters 3
Save changes With TDD1
Increment Trade Counter No
Parameter Details
152 C500-600-2.0.3

Table of Contents

Other manuals for Rinstrum C530

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rinstrum C530 and is the answer not in the manual?

Rinstrum C530 Specifications

General IconGeneral
BrandRinstrum
ModelC530
CategoryTouch Panel
LanguageEnglish

Related product manuals