Alarm ALARM Setpoint alarm. Options are:
OFF(def): no alarm.
SINGLE: Single beep alarm.
DOUBLE: Double beep alarm.
CONT.: Continuous beeping alarm.
FLASH: Flash display alarm.
Output timing TIMING Output timing. Options are:
LEVEL: Output is active when setpoint is active and reset is
not active (default)
EDGE: Output is active when setpoint is active
LATCH: will stay inactive after reset until the next setpoint
transition from inactive to active
PULSE: Setpoint will stay active once activated until the
reset becomes active
Reset input RESET Reset input. Options are:
NONE: No reset input (default)
SP.RST.A: Setpoint reset A
SP.RST.B: Setpoint reset B
32 C500-600-2.0.3