25-62 Fire Extinguisher
CAUTION
Extinguisher is rated for a max storage and operating temperature
of 120°F (49°C). If operating conditions would expose
extinguisher to higher temperatures (e.g. long term parking in
the sun in a hot climate), remove extinguisher and store it in a
cooler area between flights.
A. Inspection
Every month: Visually inspect fire extinguisher and perform weight check (a scale
with 1 gram precision or better is required). Remove extinguisher from service if
total weight falls below 500 grams. If desired, order one G654-15 decal (blank
maintenance log) and attach to extinguisher, to record weight checks.
Every 12 years: Remove fire extinguisher from service. Year of manufacture is
labeled on bottom of extinguisher; remove extinguisher from service at end of 12th
year from labeled date.
B. Bracket Removal
1. Unlatch fire extinguisher bracket and remove extinguisher.
2. Remove hardware securing bracket to chin and remove bracket.
C. Bracket Installation
1. Install hardware securing fire extinguisher bracket to chin. Select screw length
as required to provide 0.00–0.06 inch thread exposure. Verify security.
2. Install fire extinguisher and latch bracket.
APR 2019 Chapter 25 Furnishings Page 25.15