12 Rockwell Automation Publication 2198-RM003B-EN-P - November 2020
Chapter 1 Migration Options
Table 6 - Compare Ultra3000 Drive and Kinetix 5100 Servo Drive Certifications
Ultra3000 Drive
Agency Certification
(1)
Kinetix 5100 drive
Agency Certification
(1)
Standards
cULus
cULus
(2)
Ultra3000 drive:
UL Listed to U.S. and Canadian safety standards (UL 508 C File E145959).
Kinetix 5100:
UL standards for the U.S. UL61800-5-1, 1st edition, June 2012.
CSA standard for Canada. C22.2 No. 274-13
UL File Number E59272
CE CE
Ultra3000 drive:
European Union 89/336/EEC EMC Directive compliant with EN 61800-3:2004: Adjustable Speed Electrical Power Drive
Systems - Part 3; EMC Product Standard including specific test methods.
European Union 73/23/EEC Low Voltage Directive compliant with:
EN 60204-1: 1997 - Safety of Machinery - Electrical Equipment of Machines.
EN 50178: 1997 - Electronic Equipment for use in Power Installations.
Kinetix 5100 drive:
2014/30/EU, IEC/EN 61800-3: 2017 RLV,
IEC/EN 61800-3, environment 2, category C3, and EN 55011 class A group 2,
2014/35/EU, IEC/EN 61800-5-1:2016, 2006/42/EC, IEC/EN 61800-5-2:2016
— Functional Safety (FS)
Kinetix 5100 drive:
IEC/EN 61508, EN ISO 13849, IEC/EN 62061, IEC/EN 61800-5-2:2016
(CAT3, SIL 2, PLd)
KC KCC
Ultra3000 drive:
Korean Registration of Broadcasting and Communications Equipment, compliant with:
Article 58-2 of Radio Waves Act, Clause 3
Registration number: KCC-REM-RAA-2098-DSD
Kinetix 5100 drive:
Korean Registration of Broadcasting and Communications Equipment, compliant with:
• Article 58-2 of Radio Waves Act, Clause 3
• Registration number: KCC-REM-RAA-2198
— RoHS Kinetix 5100 drive: European Directive 2011/65/EU(1) - The Restriction of Hazardous Substances (RoHS), EN 50581:2012
— RCM (Formerly C-Tick)
Kinetix 5100 drive: Australian Radiocommunications Act, compliant with:
AS/NZS CISPR 11:2002 (Group 1, Class A);
Radio Communications Act: 1992;
Radio Communications (Electromagnetic Compatibility) Standard: 1998;
Radio Communications (Compliance Labeling - Incidental Emissions) Notice: 1998
— ODVA Kinetix 5100 drive: EtherNet/IP conformance tested, EtherNet/IP Specification Volume 2, Edition 1.23, April 2017
—China RoHS
Kinetix 5100 drive:
— SCCR
Kinetix 5100 drive: UL 61800-5-1 standard, short circuit test (including exception 5.2.3.6.2.1DV.2.3), and breakdown of
components test
—WEEEYes
(1) When product is marked, see rok.auto/certifications for Declarations of Conformity Certificates.
(2) UL has not evaluated the safe-off, Safe Torque Off, or safe speed-monitoring options in these products.