TTL synchronization
In addition, TTL synchronization can be used with some Rohde & Schwarz generators
connected via GPIB. The TTL interface is included in the AUX CONTROL connector of
the R&S FSW-B10 option.
Using the TTL interface allows for considerably higher measurement rates than pure
GPIB control, because the frequency stepping of the R&S FSW is directly coupled with
the frequency stepping of the generator. For details see chapter 4.7.4.7, "Coupling the
Frequencies", on page 43.
In figure 4-4 the TTL connection is illustrated using an SMU generator, for example.
Fig. 4-4: TTL connection for an SMU generator
The external generator can be used to calibrate the data source by performing either
transmission or reflection measurements.
Transmission Measurement
This measurement yields the transmission characteristics of a two-port network. The
external generator is used as a signal source. It is connected to the input connector of
the DUT. The input of the R&S FSW is fed from the output of the DUT. A calibration
can be carried out to compensate for the effects of the test setup (e.g. frequency
response of connecting cables).
Fig. 4-5: Test setup for transmission measurement