GUI Reference
R&S
®
ZNB/ZNBT
503User Manual 1173.9163.02 ─ 53
Ch<n> Calibration Properties/Cal Group <n> Properties
Displays the basic channel settings and the properties of the system error correction
and the power correction for the channel (calibration group) selected in the "Channel
State" ("Pool") table.
"Ch<n> Calibration Properties" also indicates settings mismatches (between the
selected channel and the channel setup that was used during calibration) that lead to a
"Cal Off". Currently this indication is limited to settings related to Parallel Measure-
ments with Frequency Offset and Freq Sweep Mode.
In addition, it is stated whether sweep data are available for the selected calibration.
Remote command:
[SENSe<Ch>:]CORRection:DATE?
[SENSe<Ch>:]CORRection:DATA:PARameter<Sfk>?
[SENSe<Ch>:]CORRection:DATA:PARameter<Sfk>:PORT<PhyPt>?
[SENSe<Ch>:]CORRection:DATA:PARameter:COUNt?
[SENSe<Chn>:]CORRection:SSTate?
6.12 Channel Config Softtool
The "Channel Config" functions select, create and delete channels, configure the
source and receive ports of the R&S ZNB/ZNBT, and optimize the measurement proc-
ess.
Access: CHANNEL – [CHANNEL CONFIG] hardkey
6.12.1 Channels Tab
Allows you to create and delete channels, to modify the channel state, and to select a
channel as the active channel.
You can monitor the channel activity using the OUTPut<Ch>:UPORt[:VALue] com-
mand and the output signals at pins 8 to 11 of the USER PORT connector.
Background information
Refer to Chapter 5.1.3.3, "Active and Inactive Traces and Channels", on page 83.
Channel Config Softtool