Command Reference
R&S
®
 ZNB/ZNBT
957User Manual 1173.9163.02 ─ 53
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:IO........................................................... 972
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:LOW........................................................972
CONTrol<Ch>:RFFE<Bus>:SETTings:VOLTage:HIGH.......................................................972
CONTrol<Ch>:RFFE<Bus>:TEST:DATA........................................................................... 973
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk.........................................................................973
CONTrol<Ch>:RFFE<Bus>:TEST:VIO..............................................................................973
CONTrol<Ch>:RFFE<Bus>:TEST:DATA:RANGe............................................................... 974
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk:RANGe.............................................................974
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:RANGe..................................................................974
CONTrol<Ch>:RFFE<Bus>:TEST:CLOCk:SHUNt?............................................................974
CONTrol<Ch>:RFFE<Bus>:TEST:DATA:SHUNt?.............................................................. 974
CONTrol<Ch>:RFFE<Bus>:TEST:VIO:SHUNt?.................................................................974
CONTrol:RFFE<Bus>:TEST:DATA:VOLTage?................................................................... 975
CONTrol:RFFE<Bus>:TEST:CLOCk:VOLTage?.................................................................975
CONTrol:RFFE<Bus>:TEST:VIO:VOLTage?......................................................................975
CONTrol:RFFE<Bus>:TEST:DATA:CURRent?.................................................................. 975
CONTrol:RFFE<Bus>:TEST:CLOCk:CURRent?................................................................ 975
CONTrol:RFFE<Bus>:TEST:VIO:CURRent?..................................................................... 975
CONTrol<Ch>:SEGMent<Nr>:SEQuence:COUNt?............................................................975
CONTrol<Ch>:SEGMent<Nr>:SEQuence:CLEar:ALL........................................................ 976
CONTrol<Ch>:SEGMent<Nr>:SEQuence<Nr>:DELay....................................................... 976
CONTrol<Ch>:SEGMent<Nr>:SEQuence<Nr>:GPIO<Port>:VOLTage.................................976
CONTrol<Ch>:SEGMent<Nr>:SEQuence<Nr>:RFFE<Bus>:COMMand:DATA..................... 977
CONTrol<Ch>:SEQuence:CLEar:ALL.............................................................................. 978
CONTrol<Ch>:SEQuence:COUNt?.................................................................................. 978
CONTrol<Ch>:SEQuence<Nr>:DELay............................................................................. 978
CONTrol<Ch>:SEQuence<Nr>:GPIO<Port>:VOLTage....................................................... 979
CONTrol<Ch>:SEQuence<Nr>:RFFE<Bus>:COMMand:DATA............................................979
CONTrol:AUXiliary:C[:DATA] <DecValue>
Sets or queries a channel-dependent eight-bit decimal value to control eight independ-
ent output signals at the USER PORT connector (lines 8, 9, 10, 11 and lines 16, 17, 18,
19). The output signals are 3.3 V TTL signals which can be used to differentiate
between up to 255 independent analyzer states. CONTrol:AUXiliary:C[:DATA]
itself does not change the analyzer state.
Channel bit definition and activation
The channel bits have the following properties:
●
After a *RST of the analyzer all channel bits (including the value for the active,
sweeping channel no. 1) are set to zero; no signal is applied to pins 8 to 11 and 16
to 19 of the USER PORT connector.
●
The value defined with CONTrol:AUXiliary:C[:DATA] is assigned to the
active channel (INSTrument:NSELect <Ch>).
●
The signals at the USER PORT connector reflect the channel bits of the measur-
ing channel, i.e. the channel for which the analyzer performs a sweep. This chan-
nel is not necessarily identical with the active channel.
SCPI Command Reference