EasyManua.ls Logo

Rohde & Schwarz R&S ZNB - Calculate Commands

Rohde & Schwarz R&S ZNB
1451 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command Reference
R&S
®
ZNB/ZNBT
752User Manual 1173.9163.02 ─ 53
MMEMory Commands........................................................................................ 1020
OUTPut Commands............................................................................................1062
PROGram Commands........................................................................................1067
[SENSe:] Commands..........................................................................................1070
SOURce Commands...........................................................................................1205
STATus Commands............................................................................................ 1253
SYSTem Commands...........................................................................................1256
TRACe Commands.............................................................................................1298
TRIGger Commands...........................................................................................1301
8.3.1 CALCulate Commands
The CALCulate... commands perform post-acquisition data processing. Functions
in the SENSe subsystem are related to data acquisition, while the CALCulate subsys-
tem operates on the data acquired by a SENSe function.
8.3.1.1 CALCulate:CLIMits...
The CALCulate:CLIMits... commands control the composite limit check.
CALCulate:CLIMits:FAIL?
Returns a 0 or 1 to indicate whether or not a global, composite limit check on several
traces has failed.
Since V2.20 of the R&S ZNB/ZNBT FW the result is automatically recalculated when-
ever a relevant setting is changed, i.e. a subsequent query will return the updated limit
violation state.
Example:
*RST; CALC:LIM:CONT 1 GHZ, 2 GHZ
Define an upper limit line segment in the stimulus range
between 1 GHz and 2 GHz, using default response values.
CALC:LIM:STAT ON; FAIL?
Switch the limit check on and query the result.
CALC:CLIM:FAIL?
Query the result for the composite limit check. As only one trace
is tested, the response should be equal to the previous
response.
Usage: Query only
Manual operation: See "Global Check" on page 346