Digital Standard IS-95 CDMA SMIQ
1125.5555.03 E-92.146
2.12.5 Menu IS-95 CDMA Standard - Reverse Link Signal without
Channel Coding
Menu DIGITAL STD - IS-95 provides access to settings for IS-95 CDMA signal generation. The
following figure shows the menu for generating the reverse link signal (transmit signal of mobile station)
without signal coding. The previous section showed the menu for generating the forward link signals as
well as the parameters that are identical for both modes.
Menu selection: DIGITAL STD - IS-95- MODE - REV_LINK
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
IS95
PHS
IS95
NADC
PDC
GSM
L
OFF ON
MODE... REV_LINK
SET DEFAULT
MODULATION... QPSK IS-95
TRIGGER MODE... AUTO
EXECUTE TRIGGER
TRIGGER... INT
CLOCK... INT
RATE FULL_RATE HALF_RATE
BURST RANDOMIZER OFF ON
DATA 0000
-----------------CHANGE DATA------------------
SELECT DATA LIST... CURRENT: R&STDM
COPY CURRENT DATA LIST TO...
DELETE DATA LIST...
EDIT DATA LIST...
EVEL
-30.0
dBm
PEP
- 23.3
dBm
STATE
Fig. 2-86 Menu DIGITAL STD - IS-95 - MODE - REV_LINK
STATE to CLOCK see section "Menu IS-95 CDMA-Standard- Forward Link Signal"
RATE
Selection of full-rate or half-rate transmission of modulation data. This
selection is only possible in the reverse link mode.
In the half-rate mode, only 8 of 16 power control groups of a frame are
transmitted ("power gating").
IEC/IEEE-bus command :SOUR:IS95:RATE HALF
BURST
RANDOMIZER
Switch on/off of burst randomizer. This selection is only possible during half-
rate transmission in the reverse link mode.
OFF Every second power control group is transmitted.
ON A random algorithm determines which eight of the 16 power
control groups of a frame will be transmitted.