SMIQ Utilities
1125.5555.03 2.413 E-9
2.29.4 Suppressing Indications and Deleting Memories (SYSTEM-SECURITY)
For security interests, indications can be suppressed and memories deleted in the SYSTEM-SECURITY
submenu.
Menu selection: UTILITIES - SYSTEM-SECURITY
SYSTEM
REF OSC
PHASE
PROTECT
CALIB
DIAG
TEST
MOD KEY
AUX I/O
BEEPER
INSTALL
STATE
OFF ON
ANNOTTATION FREQ OFF ON
ANNOTTATION AMPLITUDE OFF ON
CLEAR MEMORY
FREQ
100. 000 000 0
MHz
LEVEL
-30.0
dBm
GPIB
RS232
SERDATA
SECURITY
LANGUAGE
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
Fig. 2-257 Menu UTILITIES - SYSTEM-SECURITY
STATE
Selection of the SECURITY state
ON Locks the suppression of the indications. Can only be
set via IEC bus.
OFF Deactivates the interlock of the indication
suppression. The preset state is set in the transition
ONOFF, and all data stored such as settings, with
the exception of the DM lists are deleted. Can only
be set via IEC bus.
IEC/IEEE-bus command :SYST:SEC OFF
ANNOTATION FREQ
OFF All frequency indications are suppressed.
ON The frequency setting is displayed..
IEC/IEEE-bus command :DISP:ANN:FREQ ON
ANNOTATION AMPLITUDE
OFF All level indications are suppressed.
ON The level setting is displayed.
IEC/IEEE-bus command :DISP:ANN:AMPL ON
CLEAR MEMORY
Deletion of all data stored such as settings, user correction and
list settings stored, with the exception of the DM lists.
For this action, two commands are necessary at the IEC bus:
IEC/IEEE-bus command :SYST:SEC ON; SEC OFF