Utilities SMIQ
1125.5555.03 E-92.410
2.29 Utilities
The UTILITIES menu contains submenus for general functions which do not directly relate to the signal
generation.
2.29.1 IEC-Bus Address (SYSTEM-GPIB)
Submenu SYSTEM-GPIB offers access to the remote-control address. The setting range is 0 to 30. At
the point of delivery address 28 is set.
Menu selection: UTILITIES -SYSTEM -GPIB
SYSTEM
REF OSC
PHASE
PROTECT
CALIB
DIAG
TEST
MOD KEY
AUX I/O
BEEPER
INSTALL
ADDRESS
AMIQ ADDRESS
FREQ
100. 000 000 0
MHz
LEVEL
-30.0
dBm
GPIB
RS232
SERDATA
SECURITY
LANGUAGE
28
6
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
Fig. 2-254 Menu UTILITIES -SYSTEM -GPIB
ADDRESS
Input value of the IEC-bus address
IEC/IEEE-bus command :SYST:COMM:GPIB:ADDR 28
AMIQ ADDRESS
IEC/IEEE-bus address of AMIQ.