SMIQ Digital Standard NADC
1125.5555.03 2.269 E-9
(TRIGGER...) EXT RETRIGGER
INHIBIT
Setting the number of symbols for which a restart is
inhibited after a trigger event.
With TRIGGER MODE RETRIG selected, each new
trigger signal restarts the NADC signal generation.
This restart can be inhibited for the entered number
of symbols.
Example:
The entry of 1000 symbols causes new trigger
signals to be ignored for the duration of 1000 sym-
bols after a trigger event
IEC/IEEE-bus
:SOUR:NADC:TRIG:INH 1000
TRIGGER OUT 2
DELAY
Input value of delay of trigger signal at TRIGOUT 2
output compared with beginning of frame.
IEC/IEEE-bus
:SOUR:NADC:TRIG:OUTP:DEL 2
TRIGGER OUT2
PERIOD
Input value of output signal period at TRIGOUT 2
output given in frames.
IEC/IEEE-bus
:SOUR:NADC:TRIG:OUTP:PER 1
CLOCK...
Opens a window for selecting the clock source and for setting a delay.
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
NADC
PHS
IS-95
NADC
PDC
GSM
STATE
MODULATION...
TRIGGER MODE
EXECUTE TRIG
TRIGGER....
CLOCK...
POWER RAMP C>
SLOT ATTENUA
1
TCH
CLOCK SOURCE INT EXT
MODE SYMBOL BIT
DELAY 0.00 Symb
LEVEL
-30.0
dBm
PEP
- 27.6
dBm
Fig. 2-179 Menu DIGITAL STD - NADC - CLOCK..., SMIQ equipped with Modulation Coder SMIQB20
and Data Generator SMIQB11