SMIQ Digital Standard NADC
1125.5555.03 2.277 E-9
(SELECT SLOT...)
ALL_DATA
R
(UPLINK only)
Display of data contents in the 6 bit data field "Ramp".
DATA
Selection of data source for DATA fields. These fields are
regarded as a continuous field, ie a pseudo-random
sequence is fully continued from one DATA field to the next.
The following data sources are available:
PN.. PRBS data according to CCITT with periods
between 2
9
-1 and 2
23
-1.
IEEE
:SOUR:NADC:SLOT3:DATA PN15
DLIST Data from a programmable data list.
IEEE
:SOUR:NADC:SLOT3:DATA DLIS
SERDATA Data from data input SER DATA.
IEEE
:SOUR:NADC:SLOT3:DATA SDAT
Parameter SELECT DATA LIST... to EDIT DATA LIST... see menu selection BURST TYPE = TCH
Menu selection: BURST TYPE = SHORT (only available with LINK DIRECTION = UPLINK)
FREQ
100. 000 000 0
MHz
FREQUENCY
LEVEL
ANALOG MOD
VECTOR MOD
DIGITAL MOD
DIGITAL STD
LF OUTPUT
SWEEP
LIST
MEM SEQ
UTILITIES
NADC
PHS
IS95
NADC
PDC
GSM
SLOT G R SY CD SY CD V SY CD W SY CD X SY CD Y SY G2
1UP66281228124281282812122812162844
BURST TYPE... SHORT
SLOT LEVEL OFF ATTEN FULL
SET DEFAULT
-------------------BURST CONTENTS-------------------
G00H
R00H
SYNC A91 DE4A H
CDVCC 013 H
G2 00000000000H
V0H
W00H
X000H
Y0000H
--------------------CHANGE DATA -------------------
SELECT DATA LIST... CURRENT: R&STDM
COPY CURRENT DATA LIST...
DELETE DATA LIST...
EDIT DATA LIST...
LEVEL
-30.0
dBm
PEP
-27.6
dBm
POWE
SLOT
SAVE
LINK
RATE
SELE
EDIT
1
SH
Fig. 2-184 Menu DIGITAL STD - NADC - SELECT SLOT, SMIQ equipped with Modulation Coder
SMIQB20 and Data Generator SMIQB11
(SELECT SLOT...)
SHORT
(UPLINK ONLY)
BURST TYPE
Selection of burst type used to configure the selected slot.
SHORT Shortened Burst
IEC/IEEE-bus
:SOUR:NADC:SLOT2:TYPE SHOR

Table of Contents