EasyManua.ls Logo

Roland R-26 - Settings for the R-26; REC SETUP Options; PLAY SETUP Options

Roland R-26
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
92
Settings for the R-26
Category Menu item / Eect Value (default value: bold)
REC SETUP
REC MODE
Species the number of channels to record (p. 31).
* 2 CHANNEL is the only option with Audio
Interface Mode.
1 CHANNEL ,2 CHANNEL ,
4 CHANNEL ,6 CHANNEL
REC SOURCE
Selects the input device (p. 31).
1 CHANNEL ANALOG (MONO)
2 CHANNEL
INTERNAL, ANALOG,
ANALOG (MONO),
PLUG-IN
4 CHANNEL
XY+OMNI,
INTERNAL+ANALOG,
ANALOG+PLUG-N,
XY+PLG-IN
6 CHANNEL
XY+OMNI+INT,
XY+OMNI+ANALOG,
XY+ANALOG+P-IN
Audio
Interface
Mode
TO PC, FROM PC
SAMPLE RATE
Species the sampling rate for recording (p. 33).
44.1 kHz ,48.0 kHz ,
88.2 kHz ,96.0 kHz
REC FORMAT
Selects the le format for recording (p. 33).
WAV+MP3 ,MP3 128-kbps ,MP3 160-kbps
,MP3 320-kbps ,WAV 16-bit ,WAV 24-bit ,
REP-REC
Species whether Pre-Rec will be enabled (p. 34).
OFF, ON
PROJECT NAME
Species how the project name is to be assigned
(p. 34) .
DATE, NAME
AUTO START
Species the Auto Rec Start setting (p. 35).
OFF, 2 sec, 5 sec, 10 sec,
LEVEL 1, LEVEL 2, LEVEL 3
AUTO MARK
Species conditions for automatic marking (p. 49).
OFF, 5 min, 10 min, 30 min,
LEVEL 1, LEVEL 2, LEVEL 3
MAX FILE SIZE
Species the le size at which the project will be
automatically divided (p. 50).
64 MB ,128 MB ,
256 MB ,512 MB ,
1 GB ,2 GB
FILE TYPE
Species whether information about the record-
ing time and recording device will be embedded
in the WAV le (p. 35).
WAV ,BWF
PLAY SETUP
PLAY MODE
Species the order in which les will play (p. 61),
SINGLE , SEQUENTIAL , SHUFFLE
REPEAT
Species whether Repeat will be enabled (p. 62)
OFF, ON

Table of Contents

Other manuals for Roland R-26

Related product manuals