Controller functions
RES-445 Page 61
Part 1 of 3:
Action if machine
already operating,
HS band not chang.
Fault area
Fault area
Fault area 
Fault area 
(loose contact)
Check power supply
Run RESET
Replace controller
Replace controller
Replace controller
Replace controller
Replace controller
Check
plug-in jumper
Action
if machine started
for first time
Fault area
Fault area
Fault area
Fault area 
(loose contact)
Check
power supply
Run RESET
Replace controller
Replace controller
Replace controller
Replace controller
Replace controller
Check
plug-in jumper
Cause
I
R
signal missing
U
R
signal missing
U
R
and I
R
signals missing
Temperature step, down
Temperature step, up
Temperature too low/high
( section 9.3.10)
Frequency fluctuation,
inadmissible line frequency
Heatup time too long
( section 9.3.11)
Int. faut, contr. defective
Triac defective
Int. faut, contr. defective
Int. faut, contr. defective
Int. faut, contr. defective
Plug-in jumper for alarm
relay wrong
STATUS
of alarm relay
(factory set.)
Closed
Temp.
500°C
[°C]
33
66
100
133
166
200
233
Temp.
300°C
[°C]
20
40
60
80
100
120
140
Act. value
output;
Voltage [V]
0,66
1,33
2,00
2,66
3,33
4,00
4,66
Error
code
101
102
103
107
108
307
308
309
310
201
202
203
304
901
913
914
915
916
917
918
1
2
3
4
5
6
7