Starting Up the Printer
57
Mobile printer PW208NX/PW208mNX
Calibrate
Printing > Advanced > Calibrate
Adjust the media sensor level.
When there is malfunction of media detection, adjust the media sensor level (Gap and
I-mark sensor).
To adjust the media sensor, set the following items.
1 Auto-Calibration Adjust the sensor level automatically.
2 Gap Sensor Adjust the Gap sensor level manually.
3 I-Mark Sensor Adjust the I-Mark sensor level manually.
Note
If the media does not feed correctly after executing Auto-Calibration,
contact your SATO reseller or technical support center.
Auto-Calibration
Printing > Advanced > Calibrate > Auto-Calibration
For PW208NX:
For PW208mNX:
Perform auto-calibration for the selected media sensor.
Initial setting : Gap + I-Mark (PW208NX) / I-Mark (PW208mNX)
Setting options: Gap + I-Mark , Gap, I-Mark (PW208NX) / I-Mark (PW208mNX)
Gap + I-Mark: Adjust both Gap sensor and I-Mark sensor automatically.
Gap : Adjust the Gap sensor level automatically.
I-Mark : Adjust the I-Mark sensor level automatically.
Notes
When using a PW208mNX, the Auto-Calibration is set to I-Mark. You
cannot change the setting.
Before making an adjustment, set the specied media on the sensor and
close the cover. If you are using labels, remove the label from the liner.
Align it so that the media sensor does not detect the I-Mark (black mark).