User manual SCAIME: NU-soft-eNod4B-E-0716_236704-C.doc
10.2 Functional commands list
Functional command
Command code
Note
Set to idle (00
H
) response register
00
H
See § above note 1
reset*
D0
H
EEPROM storage
D1
H
Restore default settings
D2
H
Zero*
D3
H
Tare*
D4
H
Cancel tare*
D5
H
Cancel current command
D6
H
Theoretical scaling
D7
H
Zero adjustment
D8
H
Start physical calibration
D9
H
Physical calibration procedure
Calibration zero acquisition
DA
H
Segment 1 acquisition
DB
H
Segment 2 acquisition
DC
H
Segment 3 acquisition
DD
H
Store calibration
DE
H
end of calibration (physical/theoretical)
procedure
OUT1 activation/deactivation*
E6
H
only possible if the outputs are assigned to the
associated function
OUT2 activation/deactivation*
E7
H
OUT3 activation/deactivation*
E8
H
OUT4 activation/deactivation*
E9
H
zero offset adjustment
F0
H
Dynamic zero
F1
H
Preset tare*
F2
H
Init speed sensor calibration
F3
H
End speed sensor calibration
F4
H
Init belt length calibration
F5
H
End belt length calibration
F6
H
Calibration of flow rate
F8
H
Flow rate correction
F7
H
PID parameters auto-adjustment
F9
H
STOP PID
C9
H
RESTART PID
CA
H