13.2.8 Set points functioning
The following table describes the possible assignments.
bits
meaning
note
b
0
set point 1 commutation mode
0
window
only if output 1 assigned to the ‘set point’
function
1
hysteresis
b
2
b
1
set point 1 comparison measurement
00
gross
01
net
10
Sensor input control result
11
Batch
b
3
reserved (0)
b
4
set point 2 commutation mode
0
window
only if output 2 assigned to the ‘set point’
function
1
hysteresis
b
6
b
5
set point 2 comparison measurement
00
gross
01
net
10
Sensor input control result
11
Batch
b
7
reserved (0)
b
8
(or b
0
in CANopen®)
set point 3 commutation mode
0
window
only if output 3 assigned to the ‘set point’
function
1
hysteresis
b
10
b
9
(or b
2
b
1
in CANopen®)
set point 3 comparison measurement
00
gross
01
net
10
Sensor input control result
11
Batch
b
11
(or b
3
in CANopen®)
reserved (0)

Table of Contents