14.2.9 Flow rate time unit
It is possible to store the display flow rate time unit into the eNod4.
Flow rate time unit is a combination of 2 characters and there is no automatic calculation to adjust flow rate value if
modified.
In belt mode, following values are permitted for flow rate time unit parameter:
second (s)
hour (h)
Note: weight and flow rate time units lead eNod4 to handle the following flow rate units:
Gram per second (g/s)
Kilogram per second(kg/s)
Kilogram per hour (kg/h)
Ton per hour (t/h)
14.2.10 Save Tare and Zero in non-volatile memory
There are two options for saving TARE or ZERO request value in non-volatile memory. These options are accessible
through the “dosing cycle options” Object.