EasyManua.ls Logo

Seabreeze SHE9H4ZIGX - Page 47

Seabreeze SHE9H4ZIGX
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
Malfunction Description
Display
Running LED
Cooling LED
Heating LED
Frequency Drop for Heating High Temperature
Protection
H0
10 Flashes
Defrost or Oil Return Heat Mode
H1
1 Flash
Electrostatic Air Cleaning Protection
H2
2 Flashes
Compressor Overload Protection
H3
3 Flashes
System Overload
H4
4 Flashes
IPM Protection
H5
5 Flashes
Indoor Fan Motor Failure (Except for 42K Unit)
H6
14 Flashes
Compressor Desynchronizing
H7
7 Flashes
PFC Over-current Malfunction
HC
6 Flashes
Demagnetizing Protection for Compressor
HE
14 Flashes
Outdoor Fan motor Failure
L3
High Supply Voltage Protection
L9
20 Flashes
Startup Failure
Lc
11 Flashes
Compressor Phase Failure / Reverse Protection
Ld
Compressor Stalling (42K Unit Only)
LE
3 Flashes
3 Flashes
3 Flashes
Over-Speed (42K Unit Only)
LF
3 Flashes
3 Flashes
3 Flashes
Indoor and Outdoor Unit Do Not Match Each Other
LP
Phase Over-current Protection
P5
15 Flashes
Communication Error between the Drive Board and the
Main Board (42K Unit Only)
P6
16 Flashes
Module Temperature Sensor Failure
P7
18 Flashes
Module Overheat Protection
P8
19 Flashes
AC Contactor Protection (42K Unit Only)
P9
3 Flashes
3 Flashes
3 Flashes
Current Sensor Error
Pc
3 Flashes
3 Flashes
3 Flashes
Transducer Connection Protection (42K Unit Only)
Pd
3 Flashes
3 Flashes
3 Flashes
Temperature Drift Protection (42K Unit Only)
PE
3 Flashes
3 Flashes
3 Flashes
Drive Board Ambient Sensor Failure (42K Unit Only)
PF
3 Flashes
3 Flashes
3 Flashes
High Voltage Protection of DC Busbar
PH
11 Flashes
Low Voltage Protection of DC Busbar
PL
21 Flashes
AC Input Voltage Anomaly (42K Unit Only)
PP
3 Flashes
3 Flashes
3 Flashes
Capacitor Charging Circuit Error
PU
17 Flashes
Compress Phase Circuit Detection Error
(Except for 42K Unit)
U1
12 Flashes
DC Busbar Voltage Drop Error (Except for 42K Unit)
U3
20 Flashes
Reversing Valve Error
U7
Indoor fan Motor Zero-cross Detecting Error
(Except for 42K Unit)
U8
17 Flashes
Outdoor Unit Zero-cross Detecting Error
U9

Table of Contents