A01350693 Rev:P ECO: 7476 Date: 04/14/08 47
Symptom 16: The 135DE Exit Panel is in PM mode and armed, but when the door is opened, the
alarm does NOT sound.
Check the magnetic door contacts for proper operation.: Open loop when the door is open and closed loop
when door is closed.
If the magnetic contacts are working properly, replace the 135DE Exit Panel. .
Symptom 17: The 135DE Exit Panel has been working properly. Now the system seems to have
short range.
There may be a loose or broken antenna inside the Exit Panel. Inspect for physical damage to the Exit Panel
faceplate. Replace the Exit Panel.
Verify that the gain adjustment has not been changed. Readjust the gain for proper performance. .