5. Battery and Charging
SMF-MP10S User guide V1.1 Shanghai Seer Intelligent Technology Corporation 21
5. Battery and Charging
The robot is powered with a battery which can be charged automatically and manually.
5.1 Battery Parameters
Basic Performance Parameters of Battery
Nominal voltage 48V
Nominal capacity 35AH
0.2CC/0.2CD@25℃
Charge
parameters
Standard charge
current
7A 0.2C
Charge cut-off
voltage
54.6V
Maximum
continuous
charge current
20A
Discharge
parameters
Standard
discharge
current
15A 0.5C
Discharge cut-
off voltage
35.7V
Maximum
continuous
discharge
current
35A
Operating
temperatur
e
Charging
temperature
0℃-45℃
Discharging
temperature
-20℃ to 65℃
Storage temperature
0℃-40℃
Safety protection
Overcharge, over-discharge,
overcurrent, overtemperature,
short-circuit and balance
The specific threshold
setting is shown in the
battery instruction.
Communication requirements RS485
Dimension (mm) 269mm*178mm*124mm (IP65)
Weight (Kg) About 10KGS
Predicted value, subject to