o Uphole Data – The analog uphole data is reproduced exactly 0.5 seconds after the
Data Reception Pulse in firmware prior to15.14. Firmware 15.14 and newer the
analog uphole data is reproduced exactly 1 second after the Data Reception Pulse.
• The SourceLink program is used to view the following
o The Shot Status message from the Decoder
o Shot Status Message download
o GPS information before or after shot
o View Resistance measurements before or after shot
4.1.2 Start Code
Three parameters must match for a valid start code to be recognized.
• Start Code – (0-3) – All Boom Box units must be set to the same number
• Crew number – (0-250) – All Boom Box units must be set to the same number.
• Units – Decoder unit ID number must be included in the list of units of the selected group
within SourceLink.